Publication Date: 11/12/2024 Share Print

Previous Topic

Next Topic

Book Contents

Book Index

MELDEFLOC - Deferred Defect Convert Reported/Deferred Day to Local Time Zone

Deferred Defect Convert Reported/Deferred day to Local Time Zone

The MELDEFLOC Switch allows Date and Time to be entered in Zulu Time and converts the MEL Deferred Defect date in the Planning Query to Local Time using the Local Time Zone entered in the SYSLOCZONE Switch.

In the example below, the SYSLOCZONE (Main Station Location Time Zone) is configured to US/EASTERN TIME (GMT -5:00)

MELDEFLOC1

When MELDEFLOC is set to Yes, the System assumes that the Date & Time are entered in Zulu Time and converts them to Local Time.

Go to Technical Records/Update/Defect Reports and create a new Defect Report. In the example below, the defect was reported on March 24, 2016 at 00:30.

Note: The system assumes that the date time was entered in Zulu time and converts it to Local Time; (03/23/2016, 19:30).

Enter Defer Category, Date and Time and select MEL/CDL Category. In the example below, Defect was deferred on March 24th, 2016 at 00:45 GMT which is March 23, 2016 19:45 US/Eastern Time. The MEL/CDL number selected scheduled a Defer due date of 10 days from the Deferred Date. Click on Save to see Due Date.

Due Date is displayed for April 2nd, 2016; 10 days from the Local Deferred Date of March 23.

Go to Planning/Query/A/C Planning Query. Select Defect, Detail view and A/C Defect Report was created for. Select the Find button.

Find your Defect Report by A/C or Defect Number. Due Date displayed matches the one in the Defect Report.

When MELDEFLOC is set to No, the System assumes that the Date & Time are entered in Local Time as per SYSLOCZONE Switch.

In the example below, a defect report was created using same A/C and reported Defect Date/time as scenario above.

Defer report is filled out using same Defer Date/time as scenario above. However, Due Date displayed is April 3rd, 2016. The system added 10 days to the Defer Date. In this case, Date/time entered reflect Local time as per SYSLOCZONE Switch.

Planning/Query/A/C Planning Query; The Planning query results for same defect report show same Due Date.

See Also

Planning Switches

ACPLANQ - Number of Lines When Planning Prints Summary is Exported As Excel

ACROLAVG - Use A/C Rolling Average for Mean Hours and Cycles

ALWMULTTSK - Prevent Element From Being Added to a Work Order

APUMEAN - Mean APU Calculation

AUTOMANHOURSSCHEDULE - Allow AUTO_MANHOUR_SCHEDULE_JOB to Appear in Trax Database Jobs

AUTOTSKPRIORITY - Enables The Setup Of Auto Prioritize Task For Planning

CPYSCHFROMTRANS - Use Planning Transaction Schedule for T/Cs on Work Orders with a Line Status

DUEATPRJCT - Project the Due At Hours and Cycles Using the Mean Hours and Cycles

EMPATTSEQ - Employee Attendance Sign-On / Sign-Off Next Sequence

FLSCHDAYS - Run Using Flight Schedule Days Config Number

GLBLDUEDATECALC - Run Mean Hours / Run on Flight Due Date Calculation

INTERACTPLANMANHOURS - Interactive Planner Displays Man Hours per Location/Site

LBRBYHCNT - System Labor by Head Count

LivePlan - Enables the Live Planning Functionality

MANHOURSAUTOCOMP - Auto Complete Certain Fields in Man Hours Schedule Override

MANPLNFLF - Default Man Hour Schedule Planner to Location/Site of the Employee

OVNDATADAYS - Define Number of Days to Display in Overnight Station Report Tab

OVNTACMS - Overnight Station Default

PASTASCH - Create Past Absence Record

PLANBY - Allows You to Set Planning to Weekly or Monthly

PLANDEPT - Planning Department and Planning Sub Department Fields Mandatory

PLANDUE% - Planning Warning When Percent Due

PLANPNSEQ - Planning P/N Next Sequence Number

PLNAUTO7D - Activate Seven Day Forecast Automatically at Set Interval

PLNHISTML - Determine Planning History Time Limit

PLNJBDFLT - Default Planning Job Checkbox

PLNJOBACNO - Run Planning Jobs by Program Instead of Oracle Scheduler

PLNJOBQUE - Activate Planning Job by Java Queue

PLNTRNNO - Planning Transactions Sequence Number Can Only Be Changed By The Application

PN_EC_INSTDAYS - Count P/N E/Cs by E/C's Calendar Days or Part's Installed Days

SCHEDULEWORKG - Allow Work Group Selection Filter

SELFSCHLM - Self Assignment Schedule Date Range Limit

SHOPCAPNOT - Do Not Validate Against Shop Capability in the Shop Resource/Tasks Planner

SHOWDUEDT - Show Due Date Hours and Minutes

SHPPLNDLF - Default Shops Resource/Tasks Planner to the Location/Site in Employee Master

STREAMLINE - Clean Up Employee Schedules

TOEXITMS - Turn Off Exit Pop Up Message in Planning Query

TOOLWARN - Issues Warning If Tool Expires During W/O Scheduled Date Range

WOTCSCHDOVERWRITE - Overwrite existing W/O T/C Schedule Start/End Date with W/O Schedule Start/End Date

WOTRANSITCHECK - Automatic Transit Work Order Creation

YIELDCHECK - Validate W/O's Start Date is before E/C's Min Yield Date from Planning

Top of Page Publication Date: 11/12/2024 Share Print