Publication Date: 11/12/2024 Share Print

Previous Topic

Next Topic

Book Contents

Book Index

BINCATLINKPNCAT - Bin Category in Bin Master linked to P/N Category

Bin Category in Bin Master linked to P/N Category

Affected Window: w_system_tran_code

bin

 

Switch Set to Yes:

When set to Yes, users are allowed to link the Bin Category to the P/N Category. While performing a P/N Initial Load, Order Receiving, Bin Transfer, or Return to Stock transactions, parts can only be sent to Location Bins that contain the same P/N Category Type as the part. Additionally, if a P/N is flagged as Hazardous Material or Climate Controlled, the Location Bin must also have the Hazardous Material or Climate Controlled checkbox selected.

If the P/N Category does not match the Location Bin Category, or the P/N's Hazardous Material/Climate Controlled flag does not match the Location Bin checkbox, the system will prevent the user from completing the transaction.

Note: If a Bin is not setup with a Bin Category then any part can be stored in that bin, with the exception of P/Ns classified as Hazardous Material or Climate Controlled.

eMRO_Settings_Yes

For example, notice that the Bin Category via the Bin Master window is linked to the BIN/CATEGORY Transaction Code. This Bin Category transaction code contains the P/N Category Type radio buttons which are linked to the P/N Transaction radio buttons of the PNCATEGORY transaction code. The following Bin Category and the P/N Category transaction codes are both set to 'Serialized.'

BINCAT1

bn

The following Bin Category and the P/N Category transaction codes are both set to 'Consumable.'

BINCAT 2

bn2

When a Bin Transfer is carried out, the P/N Category of the part being transferred is validated against the Bin Category of the Location Bin.

The following Bin Transfer contains a Serialized part. When it is transferred to a Bin that contains a Bin Category that is not Serialized, the following error message appears.

BINCAT 3

When a serialized Bin is entered for the Bin Transfer, users are allowed to complete the transfer.

BINCAT 4

Alternatively, the following Bin Transfer contains a Consumable part. When it is transferred to a Bin that contains a Bin Category that is not Consumable, the following error message appears.

BINCAT 5

When a Consumable Bin is entered for the Bin Transfer, users are allowed to complete the transfer.

BINCAT 6

Hazardous Material and Climate Controlled checkbox:

When set to yes, this switch will also validate the Hazardous Material and Climate Controlled checkboxes of the Bin Master window.

If a P/N is flagged as Hazardous Material or Climate Controlled, via the P/N Master, Inventory tab, then the Location Bin must also have the related Hazardous Material or Climate Controlled checkbox selected. If a P/N is flagged as Hazardous Material or Climate Controlled and the Location Bin does not have the related Hazardous Material or Climate Controlled checkbox selected, an error message will appear preventing the user from completing the transaction; and inversely, if the P/N is not flagged as Hazardous Material or Climate Controlled but the Location Bin is, the system will prevent the part from being stored in that Bin.

For example, notice that the Hazardous Material checkbox is selected via the Bin Master.

BINCAT 7

The following P/N is flagged as Hazardous Material via the P/N Master, Inventory tab.

BINCAT8

A Bin Transfer takes place for the Hazardous Material part. When a Bin is entered that does not have the Hazardous Material checkbox selected, the following error message appears.

BINCAT9

When a Bin is entered that has the Hazardous Material checkbox selected, the user is allowed to complete the Bin Transfer transaction.

BINCAT10

 

Switch Set to No:

When set to No, the Bin Category cannot be linked to the P/N Category.

eMRO_Settings_No

Notice from the Bin Category transaction code that the P/N Category Type radio buttons are not available. This removal keeps users from linking Bin Categories to P/N Categories.

 

Hazardous Material and Climate Controlled checkbox:

The Hazardous Material checkbox is not selected for the Bin Master.

BINCAT1`

The P/N is flagged as Hazardous Material via the P/N Master, Inventory tab.

BINCAT12

When a Bin Transfer takes place, the system allows the Hazardous Material P/N to be transferred to a Location Bin that does not have the Hazardous Material checkbox selected.

BINCAT13

See Also

Settings Switches

ACCATALOG - A/C Catalog Configuration

ACETOPSMAN - A/C Master Etops Control Mandatory System Wide

ACFIELDS - A/C Master Make Line No. and Variable Engineering No. (fields) Mandatory

eMRO ACMASTERCOMP - Company Change via Aircraft Master

ACTIONPRIORITY - ROS Action Code Priority

ACWGTRAN - Update Config Number for the A/C weight Values History

ATATYPESER - A/C Type/Series ATA Specification Applicability

AUTOAUTHPNSWCONF - Auto authorize P/N Software Configuration

CHOMITPN - Characters to Omit in P/N

CRYPTPASS - Personal Data Encryption

CUSTOMNOTIFIC - Customize Recurrent Items Alert Notifications

DEPMNTMD - Make Depreciation Month or Code Mandatory for Rotable and Repairable Parts

DOTNETPFDFJOIN - .NET Framework PDF concatenation

EMAILPN - P/N Interchangeable, Send E-Mail for All Transactions

ETOPSRECNOTIF - Display ETOPS Notification in Extended Format

FINSYSCT - Vendor Master Make Financial Sys Country (field) Mandatory

FINSYSSITE - Vendor Master Make Financial Sys Site Code (field) Mandatory

FINSYSVEND - Vendor Master Make Financial Sys Country (field) Mandatory

GRAVELCONTROL - Gravel Ratio applied for Aircraft Landing on an Unpaved Runway

I_EMPPOS - Employee Position

I_ENAML - Employee Name

JAVAHEAP - Allows User to Set the Maximum Java Heap Size in MB

KFACTROL - Carrying Cost Factor for EOQ Calculation

LOCKDEFAULTLOGIN - Default Login Method Set in INI File

LOCVEND - Vendor Location (field) Mandatory

LOCDFTWHR - Location Default Warehouse

MELVIAREV - Update MEL Via Revision

NWPNAUTH - New P/N to Authorization

OEWUPD - Operating Empty Weight Auto Update

ONSTPAUTH - One Step Authorization for P/N

OVRPREFERVEN - Override Preferred Vendor When Manufacturer is Updated

PNACCONF - Display Hard Warning Message Upon Deletion of P/N A/C Configuration

PNCATCHN - Allow P/N Category Change without Validation of the Invoice Status

PNDNTSHW - P/N Control Do Not Cascade Show On Report Checkboxes

PNINMFMN - P/N Control Do Not Cascade Show On Report Checkboxes

PNSOFTAUTH - P/N Software to Authorization

PNSOFTEC - Control Software Configuration via P/N Software and SLID

PNVENDPOPREF - Multiple P/N Vendors Cannot be Preferred and Have Same Condition

PNVENDROAUTLOC - Auto R/O By Location

PNVENDROPREF - Only Allow One Preferred Vendor for P/N Repair Capability

PN_NHA_EFF - Enable P/N NHA Effectivity Validation

PRINTBARCODE - Print Barcode Scan Interface Sequence and Flag

PROCONTLNHA - Update Prorated Control Initial Times at Schedule Change

eMRO RANDOMBIN-Virtual Warehousing/Random binning Functionality

REOREQ_1 - Inventory Levels of min/max/reorder of 1/1/1. Reorder Qty of 1

RFACTROL - Replenishment Cost Factor for EOQ Calculation

RSTROREPCD - Links Auto Reset on R/O to Repair Code

SHLFRMV - Remove Shelf Life Expiration

SKILLDEFECT - Allow the Exclusion of Certain Skills from Appearing in the Skills

SSVIAFV - System Ship Via From Vendor Instead of Tran Code

SUBLOCATION - Allow Sub Locations on a Location for Grouping Inventory Re-Ordering

SUPERSEDPN - Superseded By Interchangeable Validation

SYSTRANCDBUF - Use System Category Edit Buffer Control

VALIDATENUMERIC - Validate Numeric Range Logic

VALLICDATE - Validate License Date

VATMNDTRY - Vendor Master Make V.A.T. (field) Mandatory

VATVALIDATE - Validate V.A.T. in Vendor Master window

VNDPRCTCATOF - Protect Vendor Q/A Checkboxes

WALLPIN - PIN required at Completion step in W/O Task Card Assignment Workshop

WOCONSUMBC - Enables/Disables Barcode in W/O Control Summary Print

Top of Page Publication Date: 11/12/2024 Share Print