Publication Date: 11/12/2024
![]() ![]() ![]() ![]() |
|||||||
The Range EC Effectivity From the Engineering Control window, select the Range EC Effectivity The system displays the Engineering Control Range window. Note: This window is affected by Switch Note: When Switch The following information/options are available in this window: Type Drop Down Select the Range Type from the drop down menu. This option allows the user to easily enter a range without having to override the E/C to the A/C S/N level. For example, this option is used when an AD states a specific range that the AD is effective to. The user does not have to override the A/C Type/Series to manually select/deselect the necessary A/C Tail Numbers. A/C - Apply effectivity by Aircraft. This information is pulled from the A/C Master, General tab. S/N (Serial Number) - Apply effectivity by specific Aircraft Serial Number. This information is pulled from the A/C Master, General tab. Line - This information is pulled from the A/C Master, Optional 2 tab. Variable No - This information is pulled from the A/C Master, Optional 2 tab. SGML Designator - This information is pulled from the A/C Master, Optional 2 tab. IPC - This information is pulled from the A/C Master, Optional 2 tab. From-To Range Enter the range of aircraft with effectivity being applied or not. Status The status that will be assigned to the range identified in the From - To fields. Reason Reason for the Schedule Effectivity to be updated/changed for the range. Source The way that the range was imported/created. This field is updated automatically. The available options are E/C, IPC, and MAN (Manual). The Source is 'MAN' when any part of the range was entered or altered manually. Created By The user who created the record. Created Date The date the record was created. Modified By The user who last modified the record. Modified Date The date the record was last modified. Status (Default for S/N out of Ranges) The default status that will be assigned to items that fall outside of the ranges specified above. Reason (Default for S/N out of Ranges) The reason applied to items that fall outside of the range specified above. _____________________________________________________________________________________
In the example below, the user selects A/C from the Type drop down and enters a range of 771 to 772. The Status for the range is set to Open and a Reason has been entered; additional ranges can be set up by selecting the New The Save From the Engineering Control window, the status for each A/C has been updated accordingly. |
|||||||
Top of Page |
Publication Date: 11/12/2024
![]() ![]() ![]() ![]() |
||||||