Publication Date: 11/12/2024 Share Print

Previous Topic

Next Topic

Book Contents

Book Index

Terminated E/C If Terminated, via Engineering Control, Schedule Controlled By Tab

The Terminate E/C If Terminated control allows users to set up multiple parent/child relationships where multiple parent E/Cs need to be terminated before terminating the child E/C.

When the last parent E/C with the Terminated E/C If Terminated control is accomplished, the system automatically writes a compliance record and terminates the child E/C. The order in which the parent E/Cs with the Terminated E/C If Terminated control are accomplished does not matter (the child E/C compliance record will reference what parent E/C caused its termination).

Note: The child E/C above has multiple Terminated E/C If Terminated parent E/C relationships. The user can see all Terminated E/C If Terminated controls under the Schedule Control tab of the child E/C.
eMRO Terminated EC if Terminated Controlled By Tab

Note: This control may be utilized multiple times to set up an unlimited number of parent/child E/C relationships.

 

Terminated E/C If Terminated example:

An AD has been issued to carryout inspection tasks against an aircraft. At the same time, there are 3 SBs that, together, encompass the same required inspection tasks as the AD. Once all 3 SBs are accomplished and terminated, the requirements for the AD inspection tasks have been met and the AD no longer needs to track against the aircraft. Upon compliance of the last (3rd) SB, the system automatically writes compliance and terminates the AD (with reference to the SB that caused it compliance).

Engineering_176

SB1 has been accomplished and terminated for A/C 901.

Terminated EC If Terminated, via Engineering Control, Schedule Control Tab- Engineering Compliance

SB2 has been accomplished and terminated for A/C 901.

Up to this point the AD for A/C 901 remains open.

SB3 is accomplished and terminated for A/C 901.

Upon SB3 being complied with, the system creates a compliance record and terminates the AD for A/C 901; the compliance record includes a Terminated E/C field which references the parent E/C (the SB) that caused the termination.

See Also

Engineering Control, Schedule Controlled By Tab

Called On, via Engineering Control, Schedule Controlled By Tab

Called On 1st, via Engineering Control, Schedule Controlled By Tab

Called On At, via Engineering Control, Schedule Controlled By Tab

Called On Repeat, via Engineering Control, Schedule Controlled By Tab

E/C To Be Activated, via Engineering Control, Schedule Controlled By Tab

E/C To Be Terminated, via Engineering Control, Schedule Controlled By Tab

E/C To Be Complied With, via Engineering Control, Schedule Control By Tab

Top of Page Publication Date: 11/12/2024 Share Print