Publication Date: 11/12/2024 Share Print

Previous Topic

Next Topic

Book Contents

Book Index

Answer Button, via Yes/No Response Type

Once the Yes/No question has been created, select the Answer emro_but_survey_answer button next to the Yes E/C Control or No E/C Control to specify the E/C Control action to be taken when the user selects that answer when answering the survey question.

eMRO Task Card Survey Window_YesNo_Answer button

eMRO_V5_gold Note: The Answer button is available for Yes/No survey questions created in the Task Card Survey window, via Engineering and the W/O Task Card Survey window, via Production.

The system will display the Task Card Survey Schedule Control Window. Use the drop down menu to select an E/C Control action and populate the E/C to be actioned.

eMRO Task Card Survey Window_Answer_Task Card Survey Schedule Control-YesNo

 

The following information/options are available in this window:
_____________________________________________________________________________________

E/C Repeat Schedule

When selected, the repeat schedule of the E/C can be changed. The E/C compliance parameter fields appear. The E/C repeat schedule parameters can be changed. Once the Survey is answered accordingly for the completed W/O T/C, the E/C's Repeat Schedule will be updated according to the values entered in the Survey.

E/C To Be Activated

Previously Terminated E/Cs can be automatically re-Activated when another E/C is Terminated depending on the setup of the Survey and the Task Card Survey Schedule Control window. For example, based on the response to the Task Card Survey below, E/C: X will be Terminated and E/C: Y will be Activated. Based on the response to the other Task Card Survey below, E/C: Y will be Terminated and E/C: X will be Activated. Now, in the event that E/C: X had previously been Terminated, the system will re-Activate it once E/C: Y is Terminated. The complied date of the Terminated E/C then becomes the Effective Date for the re-Activated E/C.

Note: When Activating an E/C that already has an effective Date, re-Activating the E/C will not change/update the original Effective Date.

E/C To Be Added

Upon providing an Answer within the From To Range, the specified Engineering Control will be added to the Work Order to which the Task Card, along with its Survey, is associated to.

E/C To Be Terminated

The user may choose the Engineering Control to be terminated from the Work Order the Task Card is associated to upon answering the Survey question within the specified Range.

Task Card To Be Added

Upon providing an Answer within the From To Range, the specified Task Card will be added to the Work Order to which the Task Card, along with its Survey, is associated to.

_____________________________________________________________________________________

 

E/C Repeat Schedule:

When the 'E/C Repeat Schedule' control is selected, the repeat schedule of the E/C can be changed.

From the Task Card Survey window, select the Answer emro_but_survey_answer button and the Task Card Survey Schedule Control window appears.

Select 'E/C Repeat Schedule' from the Control drop down options. The E/C compliance parameter fields appear and the E/C repeat schedule parameters can be edited.

eMRO Task Card Survey Schedule Control _EC Repeat Sched-YesNo

Once the survey question is answered, the E/C's Repeat Schedule will be updated according to the values entered in the Task Card Survey Schedule Control parameters.

 

Activating/Terminating E/Cs:

Previously Terminated E/Cs can be automatically re-Activated when another E/C is Terminated depending on the setup of the Survey and the Task Card Survey Schedule Control window.

For example, based on the response to the Task Card Survey, E/C: X will be Terminated and E/C: Y will be Activated.

eMRO Task Card Survey Schedule Control _ActivateTerminate-YesNo

In the event that E/C: Y had previously been Terminated, the system will re-Activate it once E/C: X is Terminated. The complied date of the Terminated E/C then becomes the Effective Date for the re-Activated E/C.

Note: When Activating an E/C that already has an effective Date, re-Activating the E/C will not change/update the original Effective Date.

See Also

Yes/No Response Type, via Task Card Survey

Notification Button, via Yes/No Response Type